Antibiotic resistance testing no longer impeded by time

Researchers from Nara Institute of Science and Technology and collaborating partners have developed a novel method for antibiotic resistance testing that might transform microbial screening in clinical and research labs

Peer-Reviewed Publication

Nara Institute of Science and Technology

IMAGE

image: Schematic of the intelligent impedance system, consisting of a parallel impedance cytometry and a machine learning-based detection system. In the case of single bacteria detection, untreated bacteria cells were measured in one channel as the reference, and antibiotic-treated cells were measured in another channel as the target particles. The lab-made lock-in amplifier measured the impedance of single cells in both channels, and sent all signals to the computer, where an intelligent system analyzed the signals in real time. The intelligent system was able to show the impedance waveforms, extract impedance magnitudes and phases, recognize susceptible cells in real time and display the result directly. view more 

Credit: Yaxiaer Yalikun

Ikoma, Japan – Significant time is needed to determine the drug susceptibility profile of a bacterial infection. Now, researchers from Nara Institute of Science and Technology and collaborating partners have published reports on a technology that will dramatically speed up this otherwise slow process and possibly help save lives.

The U.S. CDC states that antibiotic-resistant infections are responsible for killing over a million people worldwide every year. Central to managing resistant infections is quickly identifying an appropriate treatment to which the infective bacteria are susceptible. "Oftentimes susceptibility results are needed much faster than conventional tests can deliver them," says Yaxiaer Yalikun, senior author. "To address this, we developed a technology that can meet this need."

The group’s work is based on impedance cytometry which measures the dielectric properties of individual cells with high throughput – over a thousand cells per minute. Because the electrical readout of a bacterium corresponds to its physical response to an antibiotic, one has a straightforward means of determining whether the antibiotic works against the bacteria. Conventional impedance cytometry involves analyzing the test (antibiotic treated) and reference (untreated) particles in one sample followed by calibrating the impedance of the two particles – both steps require technical specialists to carry out extensive post-processing, which was a major limitation the group was determined to overcome.

In a study published in ACS Sensors, the group develops a novel impedance cytometry method that simultaneously analyses the test and reference particles in separate channels, creating easily analyzable separate datasets. This cytometry had nanoscale sensitivity, allowing for detection of even minute physical changes in bacterial cells. In a concurrent study published in Sensors and Actuators B, the group designed a machine learning tool to analyze the impedance cytometry data. Because the new cytometry method splits the test and reference datasets, the machine learning tool could automatically label the reference dataset as the “learning” dataset and use it to learn the characteristics of an untreated bacterium. By real-time comparison with antibiotic-treated cells, the tool can identify whether the bacteria are susceptible to the drug and can even identify what proportion of bacterial cells are resistant in a mixed-resistance population. "Although there was a misidentification error of less than 10% in our work, there was a clear discrimination between susceptible and resistant cells within 2 hours of antibiotic treatment," explains Yoichiroh Hosokawa, another senior author in the group.

This work is not limited to rapid evaluations of infections in clinical settings. For example, drug discovery researchers could use it to conduct quick initial investigations of drug efficacy against any cell, as long as the cellular response results in a change in dielectric properties. Impedance cytometry might become a staple of clinical and research labs in the coming years.

###

Resources

Title: Parallel impedance cytometry for real-time screening of bacterial single cells from nano- to microscale

Authors: Tao Tang, Xun Liu, Yapeng Yuan, Tianlong Zhang, Ryota Kiya, Yang Yang, Yoichi Yamazaki, Hironari Kamikubo, Yo Tanaka, Ming Li, Yoichiroh Hosokawa & Yaxiaer Yalikun

Journal: ACS Sensors

DOI: 10.1021/acssensors.2c01351

Title: Machine learning-based impedance system for real-time recognition of antibiotic-susceptible bacteria with parallel cytometry

Authors: Tao Tang, Xun Liu, Yapeng Yuan, Ryota Kiya, Tianlong Zhang, Yang Yang, Shiro Suetsugu, Yoichi Yamazaki, Nobutoshi Ota, Koki Yamamoto, Hironari Kamikubo, Yo Tanaka, Ming Li, Yoichiroh Hosokawa & Yaxiaer Yalikun

Journal: Sensors and Actuators: B. Chemical

DOI: 10.1016/j.snb.2022.132698