image: (A) Axial image from contrast-enhanced CT using positive oral contrast material, performed to monitor treatment response. Examination clinically interpreted as not showing metastatic disease. Unblinded retrospective image review shows tiny omental nodule (arrow) near bowel loops. Adequacy of bowel filling with contrast material rated very good. Both blinded retrospective readers detected nodule. (B) Axial image from contrast-enhanced CT performed two months later shows slight increase in size of nodule (arrow) and several new nodules (arrowheads), confirming lesion as missed malignant deposit. view more
Credit: American Roentgen Ray Society (ARRS), American Journal of Roentgenology (AJR)
Leesburg, VA, March 16, 2022—According to ARRS’ American Journal of Roentgenology (AJR), the selection of oral contrast agent and optimization of bowel preparation for oncologic CT could help avoid potentially severe clinical consequences of missed malignant deposits.
“CT has suboptimal NPV for malignant deposits in intraabdominal nonsolid organs,” wrote corresponding author Benjamin M. Yeh of the University of California, San Francisco. “Compared to neutral material, positive oral contrast material improves detection, particularly with adequate bowel filling.”
Yeh and team’s retrospective study included 265 patients (133 men, 132 women; median age, 61 years) who underwent an abdominopelvic CT examination where the report did not suggest presence of malignant deposits and subsequent CT examination within 6 months where the report indicated at least one unequivocal malignant deposit. Examinations used positive (iohexol; n=100) or neutral (water; n=165) oral agents. While reviewing images to assess visibility of deposits, a board-certified abdominal radiologist also assessed adequacy of bowel filling with oral contrast material.
NPV of CT for detection of malignant deposits in intraabdominal nonsolid organs was 65.8% for examinations using positive oral contrast material with adequate bowel filling, 45.2% for positive oral contrast material with inadequate bowel filling (p=.07), and 35.2% for neutral oral contrast material regardless of adequacy of bowel filling (p=.002).
“Results may differ when studying other types of contrast material regimens,” the authors of this AJR article noted, including barium-based, hyperosmolar iodine, sugar-alcohol neutral, or experimental dark oral agents.
An electronic supplement to this AJR article is available here.
North America’s first radiological society, the American Roentgen Ray Society (ARRS) remains dedicated to the advancement of medicine through the profession of medical imaging and its allied sciences. An international forum for progress in radiology since the discovery of the x-ray, ARRS maintains its mission of improving health through a community committed to advancing knowledge and skills with the world’s longest continuously published radiology journal—American Journal of Roentgenology—the ARRS Annual Meeting, InPractice magazine, topical symposia, myriad multimedia educational materials, as well as awarding scholarships via The Roentgen Fund®.
MEDIA CONTACT:
Logan K. Young, PIO
44211 Slatestone Court
Leesburg, VA 20176
703-858-4332
Journal
American Journal of Roentgenology
Method of Research
Observational study
Subject of Research
People
Article Title
Positive Versus Neutral Oral Contrast Material for Detection of Malignant Deposits in Intraabdominal Nonsolid Organs on CT
Article Publication Date
16-Mar-2022
COI Statement
Benjamin M. Yeh: Shareholder, Nextrast, Inc. Research grants: General Electric Healthcare, Philips Healthcare. Royalties: Oxford University Press, UCSF patents. Consultant: General Electric Healthcare, Canon Medical Systems. Speaker: General Electric Healthcare, Philips Healthcare, Canon Medical Systems.