News Release

3D spiral sequence overcomes conventional challenges for head and neck MRI

AJR: 3D spiral gradient recalled echo improves subjective image quality and contrast-to-noise ratio of head and neck MRI with shorter scan time versus Cartesian sequences, though exhibits larger dental material artifact

Peer-Reviewed Publication

American Roentgen Ray Society

56-Year-Old Woman Who Underwent MRI of Head and Neck

image: Examination included spiral gradient recalled echo (GRE) (A), Cartesian GRE (B), and Cartesian turbo spin echo (TSE) (C) sequences. Artifact is present in left paranasal region due to dental material. Artifact measures (mean of three manual measurements) 30.1 mm on spiral GRE, 26.3 mm on Cartesian GRE, and 22 mm on Cartesian TSE. view more 

Credit: American Roentgen Ray Society (ARRS), American Journal of Roentgenology (AJR)

Leesburg, VA, August 25, 2021According to an open-access Editor’s Choice article in the American Journal of Roentgenology (AJR), a 3D spiral gradient recalled echo (GRE) sequence could help conquer certain challenges of conventional Cartesian sequences for head and neck MRI.

“3D spiral GRE improves subjective image quality and contrast-to-noise ratio (CNR) of head and neck MRI with shorter scan time versus Cartesian sequences, though exhibits larger dental material artifact,” wrote corresponding author Sabine Sartoretti-Schefer from the Institute of Radiology at Kantonsspital Winterthur in Switzerland.

From August 2020 to May 2021, Sartoretti-Schefer and team prospectively studied patients referred for contrast-enhanced head and neck MRI. Patients underwent 1.5-T MRI (Ingenia; Philips Healthcare, Best, the Netherlands), including contrast-enhanced [Gadovist (Gadobutrol) 1.0 mmol/mL, Bayer HealthCare Pharmaceuticals, 0.1 mL/kg body weight] spiral GRE (2:28 min), Cartesian GRE (4:27 min), and Cartesian turbo spin echo (TSE) (3:41 min) sequences, acquired in rotating order to mitigate bias.

Among 31 patients (13 male, 18 female; mean age, 63.8 years) who underwent head and neck MRI, spiral GRE, compared with Cartesian GRE and Cartesian TSE, achieved improved image quality for numerous subjective measures for three independent readers and improved CNR, with 33.0%–44.6% reduced scan time. However, maximal extent of dental material artifact was greatest for spiral GRE.

Reiterating that the 3D spiral GRE sequence “exhibited larger susceptibility artifacts in association with dental material,” the authors of this AJR article expressed special consideration for patients with dental implants or fillings.

An electronic supplement to this AJR article is available here.


Founded in 1900, the American Roentgen Ray Society (ARRS) is the first and oldest radiological society in North America, dedicated to the advancement of medicine through the profession of radiology and its allied sciences. An international forum for progress in medical imaging since the discovery of the x-ray, ARRS maintains its mission of improving health through a community committed to advancing knowledge and skills with an annual scientific meeting, monthly publication of the peer-reviewed American Journal of Roentgenology (AJR), quarterly issues of InPractice magazine, AJR Live Webinars and Podcasts, topical symposia, print and online educational materials, as well as awarding scholarships via The Roentgen Fund®.

MEDIA CONTACT:

Logan K. Young, Marketing & Communications

44211 Slatestone Court

Leesburg, VA 20176

703-858-4332

lyoung@arrs.org


Disclaimer: AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert system.