Rotor vibration on the 1 RMB side ( 1 X and 1 Y DOFs) using AFCs based on LUT. (a) 1 X DOF. (b) 1 Y DOF. (IMAGE)
Caption
The rotor vibration on the 1 RMB side ( 1 X and 1 Y DOFs) is illustrated in Fig. It‘s shown from Fig that the AFCs with LUT achieve convergence within 0.35 s, which shows an extremely short transient process compared with AFCs based on ISA. Moreover, the rotor vibration is the same as it was with the AFCs based on ISA. Possessing both convergence speed and suppression effectiveness, AFCs using LUT can be applied in variable speed condition.