News Release

Controlling bleeding disorders with fitted hydrogel casts

A hydrogel easily injected into blood vessels could help stop uncontrolled bleeding, even in patients on blood-thinners or with bleeding disorders

Peer-Reviewed Publication

Wyss Institute for Biologically Inspired Engineering at Harvard

(Boston) -- Small blood clots called emboli are mostly known for traveling through the vasculature before they lodge and obstruct vessels, impeding blood and oxygen supply to organs like the lung. To stop excessive bleeding or the flow of blood into an aneurysm, clinicians harness the same principle by forming artificial therapeutic emboli that can plug blood-carrying vessels. Using steerable catheters, they place tiny soft metal coils or liquid embolic agents ('glues') into the affected artery to block the passage of blood.

However, both procedures do not come without problems and risks. Coil embolization can be ineffective if the coil is not positioned or seized accurately and coils need efficient blood clotting in patients to be stabilized. Liquid embolic agents on the other hand can be accidentally cemented to catheters or non-targeted areas due to insufficient control of their solidification. And, importantly, both types of emboli can become leaky over time.

A team of researchers at Harvard's Wyss Institute for Biologically Inspired Engineering, Brigham and Women's Hospital, the Mayo Clinic and MIT now describe a new class of hydrogel-based embolic agents, which could help eliminate all these caveats. Their study, published in Science Translational Medicine, provides proof-of-concept and first preclinical evidence in animal models that the shear-controlled hydrogel can be delivered by catheters and injected into blood vessels to form robust and safe blockages.

"This new approach to vascular embolization is based on a hydrogel composite with phase properties we can reliably control with mechanical pressure. It completely blocks vessels in situations where other methods can fail such as in vascular areas that are highly convoluted or subject to unusual blood pressures, and, importantly, it still works when normal blood coagulation is impaired like in patients receiving blood-thinners or suffering from an intrinsic inability to efficiently form blood clots," said Ali Khademhosseini, Ph.D., who is an Associate Faculty member of the Wyss Institute, and a Professor at the Harvard-MIT's Division of Health Sciences and Technology and Brigham and Women's Hospital.

In 2014, Khademhosseini, together with Bradley Olsen, Ph.D., an Associate Professor of Chemical Engineering at MIT and also an author on the present study, reported the so-called Shear-Thinning Biomaterial (STB) and demonstrated that, when applied in bulk to larger wound surfaces, it can seal them off to halt bleeding.

The STB is a mixture of two components that form a malleable hydrogel: gelatin molecules combined with small discs of silicate nanoplatelets that mimic the function of actual platelet cells to promote blood clotting reactions. When the STB is put under mechanical pressure for example by pressing it through a syringe, it flows or 'thins'; when the pressure abates, it again solidifies, this time to create a tight barrier.

In the present study, initiated together with Rahmi Oklu, M.D., Ph.D., FSIR, an interventional radiologist at Massachusetts General Hospital, the team investigated the possibility of delivering the STB via standard catheters directly within difficult-to-reach locations of the body's vasculature to block blood flow in targeted vessels. Oklu is now an Associate Professor at the Mayo Clinic and co-corresponded the study with Khademhosseini.

Setting the stage, the researchers first optimized the formulation of the STB for effective delivery by clinical catheters and needles. They also tweaked the STB to ensure it gelled on desirable time scales without any risk of inadvertent cementing to the delivering catheter, creating a complete blockage and to confirm that the artificial clot still formed in the presence of anti-coagulants.

The optimized STB was taken into in vivo studies in mice and pigs with more human-like vascular architectures. "In the animals, we saw that STBs, delivered with standard clinical catheters into centrally located vessels, formed very effective casts, without leaking or fragmenting, excluding any risk of pulmonary embolisms down the line," said Reginald Avery, the first author of the study who did this work as a graduate student with Khademhosseini and Olsen. "Moreover, the induced embolization was biodegraded and remodeled into more natural tissue by infiltrating cells over time."

Another key advantage that STBs hold over commonly performed embolization with coils is that they can be linked to contrast agents, which allows clinicians to follow their success in patients with contrast imaging methods and to make ad hoc corrections if necessary. The team believes that in the future STBs could also be coupled to specific stimuli that attract additional immune cells and accelerate remodeling of the clot.

"This new mechanoresponsive material-based approach to therapeutic vascular embolization represents a exciting new advance for embolization therapy, and it potentially offers a great advantage for treatment of patients with clotting disorders who now have limited other options," said Donald Ingber, M.D., Ph.D. the Institute's Founding Director and the Judah Folkman Professor of Vascular Biology at Harvard Medical School and Boston Children's Hospital, and Professor of Bioengineering at the Harvard John A. Paulson School of Engineering and Applied Sciences.

###

MULTIMEDIA AVAILABLE

PRESS CONTACT
Wyss Institute for Biologically Inspired Engineering at Harvard University
Benjamin Boettner, benjamin.boettner@wyss.harvard.edu, +1 917-913-8051

MULTIMEDIA CONTACT
Wyss Institute for Biologically Inspired Engineering at Harvard University
Seth Kroll, seth.kroll@wyss.harvard.edu, +1 617-432-7758

The Wyss Institute for Biologically Inspired Engineering at Harvard University uses Nature's design principles to develop bioinspired materials and devices that will transform medicine and create a more sustainable world. Wyss researchers are developing innovative new engineering solutions for healthcare, energy, architecture, robotics, and manufacturing that are translated into commercial products and therapies through collaborations with clinical investigators, corporate alliances, and formation of new startups. The Wyss Institute creates transformative technological breakthroughs by engaging in high risk research, and crosses disciplinary and institutional barriers, working as an alliance that includes Harvard's Schools of Medicine, Engineering, Arts & Sciences and Design, and in partnership with Beth Israel Deaconess Medical Center, Brigham and Women's Hospital, Boston Children's Hospital, Dana-Farber Cancer Institute, Massachusetts General Hospital, the University of Massachusetts Medical School, Spaulding Rehabilitation Hospital, Boston University, Tufts University, Charité - Universitätsmedizin Berlin, University of Zurich and Massachusetts Institute of Technology.


Disclaimer: AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert system.