News Release

Super-small needle technology for the brain

Dissolvable material expands opportunities for flexible microneedles used for brain penetrations

Peer-Reviewed Publication

Toyohashi University of Technology (TUT)

Microneedles

image: This image shows flexible high-aspect-ratio microneedles penetrating brain tissue. view more 

Credit: COPYRIGHT(C)TOYOHASHI UNIVERSITY OF TECHNOLOGY. ALL RIGHTS RESERVED

Microscale needle-electrode array technology has enhanced brain science and engineering applications, such as electrophysiological studies, drug and chemical delivery systems, and optogenetics.

However, one challenge is reducing the tissue/neuron damage associated with needle penetration, particularly for chronic insert experiment and future medical applications. A solution strategy is to use microscale-diameter needles (e.g., < 5 μm) with flexible properties. However, such physically limited needles cannot penetrate the brain and other biological tissues because of needle buckling or fracturing on penetration.

A research team in the Department of Electrical and Electronic Information Engineering and the Electronics-Inspired Interdisciplinary Research Institute (EIIRIS) at Toyohashi University of Technology has developed a methodology to temporarily enhance the stiffness of a long, high-aspect-ratio flexible microneedle (e.g., < 5 μm in diameter and > 500 μm in length), without affecting the needle diameter and flexibility in tissue. This has been accomplished by embedding a needle base in a film scaffold, which dissolves upon contact with biological tissue. Silk fibroin is used as the dissolvable film because it has high biocompatibility, and is a known biomaterial used in implantable devices.

"We investigated preparation of a silk base scaffold for a microneedle, quantitatively analyzed needle stiffness, and evaluated the penetration capability by using mouse brains in vitro/in vivo. In addition, as an actual needle application, we demonstrated fluorescenctce particle depth injection into the brain in vivo,and confirm that by observing fluorescenctce confocal microscope" explained the first author, master's degree student Satoshi Yagi, and co-author PhD candidate Shota Yamagiwa.

The leader of the research team, Associate Professor Takeshi Kawano said: "Preparation of the dissolvable base scaffold is very simple, but this methodology promises powerful tissue penetrations using numerous high-aspect-ratio flexible microneedles, including recording/stimulation electrodes, glass pipettes, and optogenetic fibers." He added: "This has the potential to reduce invasiveness drastically and provide safer tissue penetration than conventional approaches."

###

Reference:

Satoshi Yagi, Shota Yamagiwa, Yoshihiro Kubota, Hirohito Sawahata, Rika Numano, Tatsuya Imashioya, Hideo Oi, Makoto Ishida, and Takeshi Kawano (2015). Dissolvable base scaffolds allow tissue penetration of high-aspect-ratio flexible microneedles. Advanced Healthcare Materials. Article first published online: 2 AUG 2015 | DOI: 10.1002/adhm.201500305

Further information

Toyohashi University of Technology
1-1 Hibarigaoka, Tempaku
Toyohashi, Aichi Prefecture, 441-8580, JAPAN
Inquiries: Committee for Public Relations
E-mail: press@office.tut.ac.jp

Toyohashi University of Technology, which was founded in 1976 as a National University of Japan, is a leading research institute in the fields of mechanical engineering, advanced electronics, information sciences, life sciences, and architecture.

Website: http://www.tut.ac.jp/english/


Disclaimer: AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert system.